NV10 Neonatal Ventilator

Increase NIV Confidence Further than Ever

COMEN NV10 includes a complete NIV set with specialized ventilation tools for neonates and children, expanding the ventilation strategies to protect each spontaneous breath. It offers a robust ventilation system and elevates oxygenation level at all stages.

  • HFNC + ROX – ROX index to optimize ventilation strategy.
  • nCPAP + Apnea Auto-relief – Preset compulsory pressure-controlled ventilation after apnea detected
  • DuoVent – Increase mean airway pressure (MAP) while maintain free breath.
  • 2 Sync SNIPPV + Back Up Vent – Selectable synchronization methods to catch the breath at all times.
  • NIPPV – Sustained alveolar ventilation during episodes of apnea
  • Single-limb nHFO – Patented diaphragm ocssilator with single-limb ventilation to create a safety net for NIV

Product Description

Oscillation Therapy Revolution

  • Multiple Benefits of nHFO Raise Profile in Clinical Research and Practice

The advantages of non-invasive high-frequency oscillation encompass enhanced carbon dioxide elimination, reduced dead space during ventilation, and effective treatment of persistent pulmonary hypertension (PPHN) when used with nitric oxide. There is a growing amount of academic research focusing on the benefits of non-invasive high frequency ventilation in new-born.

  • Minimization of Work of Breath in Every Detail

A single-limb setup, as opposed to a dual-limb configuration with a Y-piece and doubled tubing cavity, effectively reduces dead space, thereby decreasing the work of breathing of patients.

  • Unique Oscillator Design

The generation mechanisms on the market today are diaphragm oscillation piston type, bi-directional jet and high frequency flow-interrupter with expiration assist. NV10 adopts the most recognized method, diaphragm oscillation, and applied Comen’s unique and advance design which provide a quieter and more powerful oscillator, Covering all the scenario in practice.

Sensitively Respond to Patients Every Breath

  • 2 Sync Modes with Unique Algorithm

The abdominal sensor is designed for quick response and cost-effectiveness. The pressure sensor minimizes false activations due

  • Apnea management

Data indicates that preterm infants with a gestational age of less than 29 weeks have an asphyxia risk nearing 100%. Both nCPAP and SNIPPV modes employ dual methods with a variety of parameters to closely monitor a patient’s respiratory condition, ensuring timely detection of any signs of apnea from all monitored parameters.

Targeted Pressure as Needed

  • Leakage Compensation System

The NV 10 is equipped with a leakage compensation system up to 100% pressure compensatory, ensuring that patients receive the set pressure in the event of leakage.