NV10 Neonatal Ventilator
Increase NIV Confidence Further than Ever
COMEN NV10 includes a complete NIV set with specialized ventilation tools for neonates and children, expanding the ventilation strategies to protect each spontaneous breath. It offers a robust ventilation system and elevates oxygenation level at all stages.
- HFNC + ROX – ROX index to optimize ventilation strategy.
- nCPAP + Apnea Auto-relief – Preset compulsory pressure-controlled ventilation after apnea detected
- DuoVent – Increase mean airway pressure (MAP) while maintain free breath.
- 2 Sync SNIPPV + Back Up Vent – Selectable synchronization methods to catch the breath at all times.
- NIPPV – Sustained alveolar ventilation during episodes of apnea
- Single-limb nHFO – Patented diaphragm ocssilator with single-limb ventilation to create a safety net for NIV
Product Description
Oscillation Therapy Revolution
- Multiple Benefits of nHFO Raise Profile in Clinical Research and Practice
The advantages of non-invasive high-frequency oscillation encompass enhanced carbon dioxide elimination, reduced dead space during ventilation, and effective treatment of persistent pulmonary hypertension (PPHN) when used with nitric oxide. There is a growing amount of academic research focusing on the benefits of non-invasive high frequency ventilation in new-born.
- Minimization of Work of Breath in Every Detail
A single-limb setup, as opposed to a dual-limb configuration with a Y-piece and doubled tubing cavity, effectively reduces dead space, thereby decreasing the work of breathing of patients.
- Unique Oscillator Design
The generation mechanisms on the market today are diaphragm oscillation piston type, bi-directional jet and high frequency flow-interrupter with expiration assist. NV10 adopts the most recognized method, diaphragm oscillation, and applied Comen’s unique and advance design which provide a quieter and more powerful oscillator, Covering all the scenario in practice.
Sensitively Respond to Patients Every Breath
- 2 Sync Modes with Unique Algorithm
The abdominal sensor is designed for quick response and cost-effectiveness. The pressure sensor minimizes false activations due
- Apnea management
Data indicates that preterm infants with a gestational age of less than 29 weeks have an asphyxia risk nearing 100%. Both nCPAP and SNIPPV modes employ dual methods with a variety of parameters to closely monitor a patient’s respiratory condition, ensuring timely detection of any signs of apnea from all monitored parameters.
Targeted Pressure as Needed
- Leakage Compensation System
The NV 10 is equipped with a leakage compensation system up to 100% pressure compensatory, ensuring that patients receive the set pressure in the event of leakage.